Errors
O
ccasionally errors and warnings may be displayed on the screen. If
more than one error is triggered the arrow keys can be used to scroll
between the errors and warnings. The top right displays the current and
total number of errors with the most recent being shown first. To reset
the errors and warnings hold down the start button for 3 seconds. If the
errors and warnings do not reset then the underlying problem must be
addressed first. The error or warning can then be successfully reset.
When errors are triggered the error is displayed, the heater will shut
down and the red light on the keypad will be turned on. When a warning
is triggered it will display the message but it will not impede the function
of the heater.
Warning /Error Message Example:
MENU
SE
L
ECT/SA
V
E
START
STO
P
WARNING 006 1/3
Critical Low
System Voltage
HOLD
to RESET
Error/Warning Message
Error/Warning
Error/Warning no. (see table)
Displaying Message 1 of 3
Reset Error/Warning
Instructions (hold
for 3 seconds)