5

4

Introduction & Overview

CHAPTER 1: INTRODUCTION & OVERVIEW

1.1 Product Overview

SureCall’s Guardian2 QR is a bi-directional communications amplifier for police headquarters, fire stations, hospitals, 
and other first-responder facilities. The BDA services the full public safety 700MHz and 800MHz bands.
The Guardian2 QR significantly improves the quality of crucial first-responder communications in buildings with weak 
signal strength. For optimal coverage, the BDA uses built-in safeguards to eliminate interference to public-safety 
networks. It meets NEMA 4 type requirements, and is upgradable in the field. Plus, the Guardian2 QR offers the 
industry’s best three-year warranty available.
The Guardian2 QR is enclosed in a NEMA-4 compatible housing, and enhances the coverage area of first responder 
radio communications for in-building applications. It is equipped with bi-directional paths (down-link & up-link) for 
transmit and receive frequencies, and advanced filtering technology for low-noise amplification of signals.

1.2 Package Contents

Your BDA box contains the following items:
•  Guardian2 bi-directional amplifier
•  NEMA-4 rated housing
•  AC power cable
•  DC power cable and connector
•  Alarm cable and connector
•  Ethernet connector
•  Mounting kit 

1.3 Additional Items Needed

The Guardian2 QR needs the following additional components for a complete install:
•  External antenna
•  Lightning protector
•  Cable splitter if installing multiple antennas
•  Sufficient SC-400 ultra-low loss interior/exterior cable, 50 ohm
•  Multiple antennas (omnidirectional domes and/or panels by SureCall)
•  Grounded surge suppressor for DC power supply

1.4 Key Features & Benefits

•  Suitable for large coverage areas.
•  Extends signals in areas with poor coverage due to geographical location and/or building design.
•  Powerful in-building BDA with 31dB of adjustable gain level.
•  NEMA-4 rated amplifier housing. No additional NEMA enclosure required.
•  Integrated 7-pin alarm and UPS port for external battery backup.
•  Power control maintains maximum output power at 26 dBM.

•  Automatic oscillation detection and protection system powers down the BDA to prevent harmful radio 

interference.

•  Automatic gain control (AGC).
•  Features built-in SureCall Sentry remote-monitoring system with Ethernet port.

1.5 Optional Accessories

SureCall provides many optional features and accessories for the Guardian2 QR Amplifier. See table below:

Splitters and Couplers

SC-WS-2

Wide Band 2 Way Splitter

SC-WS-3

Wide Band 3 Way Splitter

SC-WS-4

Wide Band 4 Way Splitter

SC-C-6

-6dB Coupler

SC-C-10

-10dB Coupler

Outdoor Antenna Options

SC-288W

Wide Band Omni-directional 50 ohm Fiberglass Antenna 3 to 4dBi (includes mounting kit, 698-2700 MHz)

SC-230W

Wide Band Yagi Directional 50 ohm Antenna 10 to 11dBi gain (includes mounting kit, 698-960 & 1710-2700 MHz)

Inside Antenna Options

SC-222W

Wide Band Dome 50 ohm Antenna - 3 to 4dBi (includes mounting kit, 698 -2700 MHz)

SC-248W

Wide Band Panel 50 ohm Antenna - 7 to 10dBi (includes mounting kit,  698-2700 MHz)

Plenum Cable

SC-PL-30FT

30' SC400 Ultra Low Loss Coax Plenum Fire Rated Cable with N-Male connectors - Orange

SC-PL-75FT

75' SC400 Ultra Low Loss Coax Plenum Fire Rated Cable with N-Male connectors - Orange

SC-PL-1000FT

1000' SC400 Ultra Low Loss Coax Plenum Fire Rated Cable - Orange

Ultra Low Loss Cable
SC-006-1000

1,000' SC600 Ultra Low Loss Coax Cable. Connectors not included - Black

Accessories & Connectors

SC-LP

Lightning Protector

SC-ATNR-5

5 dB RF Attenuator

SC-ATNR-10

10 dB RF Attenuator

SC-ATNR-20

20 dB RF Attenuator

SC-CN-09

N Male Crimp Connector, 400 and Plenum Cable

SC-CN-12

N Male to N Male Connector

SC-CN-16

N Male Connector, 600 Cable

SC-Mount-Pole

L Bracket mount with U bolt hardware for donor antenna mount to J-bar

SC-Mount-JBar

Steel 1 inch J-Bar mount for donor antenna.  Antenna mount not included  

Introduction & Overview

Summary of Contents for Guardian2 QR

Page 1: ...SureCall Guardian2 QR Quick Response User and Installation Guide Public Safety Bands BDA for First Responders Supports 700 MHz FirstNet Ready and 800 MHz bands 07 13 2018 ...

Page 2: ...h registration will be available to the public on the same day it is filed with the Commission Registrations may be accessed at www fcc gov signal boosters registration Click on View All Boosters from the Part 90 Signal Booster Registration and Discovery page The registrations can be searched and sorted by booster ID number name of the filer city county state zip code latitude longitude or call si...

Page 3: ...ue to geographical location and or building design Powerful in building BDA with 31dB of adjustable gain level NEMA 4 rated amplifier housing No additional NEMA enclosure required Integrated 7 pin alarm and UPS port for external battery backup Power control maintains maximum output power at 26 dBM Automatic oscillation detection and protection system powers down the BDA to prevent harmful radio in...

Page 4: ...e working in high locations such as roofs and or ladders Follow applicable safety regulations and best practices to avoid falling Take care not to drop objects from any high area Cordon off ground areas directly below the section of roof you are working on or below your ladder whenever possible In addition as a qualified installer you are responsible for knowing and following all applicable codes ...

Page 5: ...o AC 110V 60Hz Male on BDA A5 1 2 3 L N E 1 2 3 L N E Female used to connect to 110VAC or 110V of UPS output Male pinout on BDA A5 Pin Number Definition Full Name Color Note 1 L Live Wire Black 2 N Neutral Wire White 3 E Earth Wire Green 2 4 DC12 20V Interface A9 Female used to transfer to DC 12 20V Male on BDA A9 1 2 DC DC 1 2 D C D C Female used to connect to 110VAC or 110V of UPS output Male pi...

Page 6: ...11 10 2 6 Alarm I O Interface A2 Male Alarm Connector used to transfer to Fire Department Control Box Female Alarm Connector A2 on BDA 1 2 3 4 5 6 7 Dry Contact RF Module Summary Alarm Normally Closed External Alarm IN 2 External Alarm IN 1 Dry Contact VSWR Alarm Normally Closed Dry Contact VSWR Alarm Normally Closed Dry Contact RF Module Summary Alarm Normally Closed External Alarm IN GND 2 1 5 4...

Page 7: ...tion To A2 ALARM I O pins6 To A2 ALARM I O pins3 No connection Relay Shown In Non Alarm Condition Relay Shown In Alarm Condition Dry Contact VSWR in Non Alarm Relay connection Fig in Non Alarm Condition Contacts pins3 of A2 pins6 of A2 CLOSE Dry Contact VSWR in Alarm Relay connection Fig in Alarm Condition Contacts pins3 of A2 pins6 of A2 OPEN BDA Interface Connections 2 10 Ethernet Interface A4 M...

Page 8: ...uipment after initialization unplug the USB cable As shown the NEMA housing must be open to gain access to this port The interface is used to initialize network connections using a computer Be sure to unplug the USB cable after the network initialization is completed TO A7 TO Computer USB Alarm LEDs Definitions Conditions 2 12 Alarm LEDs A8 Status Description Note POWER Green ON Normal OFF Missing...

Page 9: ... and other components Important Installation Safety Precautions The exterior antenna must not be co located or operating in conjunction with any other antenna Always use a properly installed SureCall lightning protector between the exterior antenna and the BDA Always power off the BDA before working on the roof of the building or anywhere in close proximity to the external antenna Comply with all ...

Page 10: ...ation Planning the Installation Planning the Installation horizontally try raising the exterior antenna You may also try reducing the BDA gain as described in Chapter 5 of this manual Antenna Safety Precautions You can mix and match dome and directional antennas as needed to obtain proper coverage throughout the building or area where you need to boost the signal If you use a Yagi exterior antenna...

Page 11: ...e are a few reminders and essential steps A Yagi antenna is mounted horizontally with drip hole facing down and aimed at the desired radio tower line of sight Mount the antenna Connect a length of cable to the antenna and hand tighten Run the cable along the planned route Install a properly grounded SC LP lightning protector Seal any exterior cable entry points on building exterior with caulking o...

Page 12: ...portant to keep the cable runs equal or use taps to ensure a harmonious install CAUTION VERIFY THAT ALL INTERIOR ANTENNAS MEET THE SEPARATION REQUIREMENTS DESCRIBED IN THE PREVIOUS CHAPTER AND THAT NO ANTENNA IS AIMED TOWARD THE EXTERIOR ANTENNA CAUTION DO NOT CONNECT AN INTERIOR ANTENNA TO THE SPLITTER INPUT Installation 4 4 Mounting the BDA Mount the Guardian2 QR as follows Verify that the selec...

Page 13: ...t booster switches with high but not full attenuation as full attentuation would cause the band to shut off DURING CONFUGURATION you may add gain incrementally until the signal level has improved enough to meet safety requirements Note that red flashing lights indicate the system has detected oscillation for the corresponding channel s The band will turn off stop working if adjustments are not mad...

Page 14: ...e in the building As a general rule increasing gain by 6dB doubles the coverage distance of the interior antennas Start at the lowest gain and increase gradually as needed If one or more red Warning lights comes on it indicates there is oscillation in that band and adjustments are needed If you can t get the coverage reasonably well balanced you may need to install an additional interior antenna a...

Page 15: ...software from your device supplier or download the software here http www surecall com product Sentry html Install the software using the steps outlined below Configure the server to a static IP or public IP address In order to function on the network correctly the server and the Guardian2 QR device must be a on the same Local Area Network or b the server must be the front end to the device Use ap...

Page 16: ... as shown below Sentry Configuration Monitoring The above screen confirms the installation folder and shortcut folder where you can access the Sentry software Click Next to proceed with the installation The software will now install A launch icon will be placed on your Desktop When the process is complete you ll should see the Installation Successful screen as shown below This verifies that the Se...

Page 17: ...Before you install the hardware you ll first need to register an account Connect your computer to the network where the Guardian2 QR Ethernet connection was made A secure LAN connection is important because it will allow the computer to see the Guardian2 QR device on the network Start the Sentry client application by clicking on the shortcut that resulted from installing the software You will see ...

Page 18: ... can be connected to the server Dynamic IP is available by checking Auto Search IP function OR OR enter IP parameters manually if the device needs a static IP Click Apply to finish the configuration The following summary screen appears if the booster connects to the server successfully Sentry Configuration Monitoring Column Definitions Attenuation Manually adjusted attenuation via software Manual ...

Page 19: ...DEVICE AND BY SOFTWARE CANNOT EXCEED 25 DB Another feature is E mail Alert meaning that the user will receive an e mail if an alert occurs Modify Booster Information To modify the booster information right click to access a pop up menu with the following additional options Select Edit Booster Info to proceed Sentry Configuration Monitoring Delete Booster To delete a booster right click on the summ...

Page 20: ...lect your device and right click to access a pop up menu with additional options as shown below Select Antenna Position Debug You will see the following Debug Tool screen Sentry Configuration Monitoring Place the antenna in the appropriate position and click Measure to read the current RSSI value Then try putting the antenna in 5 different positions read their respective 5 RSSI values and click Co...

Page 21: ...io or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult...

Page 22: ...Warranty CHAPTER 10 WARRANTY Activate your product warranty at www surecall com For questions regarding your warranty contact a SureCall representative at 1 888 365 6283 or email support surecall com 10 1 Warranty Periods Your warranty includes the following periods Three Year Product Warranty SureCall products are covered under a three year product warranty from the date of purchase This protects...

Page 23: ...SureCall Inc 48346 Milmont Drive Fremont California 94538 USA 888 365 6283 www surecall com ...

Reviews: