PIR & Ultrasonic Occupancy Sensor
CDL-608R12 embodies the technology of infrared and ultrasonic motion
detection into one easy-to-install occupancy sensor. Mounted at a height
of 2.4m, this sensor detects people moving within 8m diameter of a full
circular coverage area.
CDL-608R12 can be surface mounted or flush mounted for an attractive,
un-obstructive appearance. One or many sensors can be connected with
Suren's (or compatible) power packs to control a wide range of load types,
including lighting or HVAC devices.
The sensor becomes operational 30 seconds after power is supplied.
When a person enters a room, t he sensor detects major body motion and
turns the light on. The light is kept on even as smaller body movement is
detected. The sensor's
(DSL) minimizes
false triggering by adjusting detection sensitivity based upon sequence of
occupancy events. The
provides additional control such
that lighting is not activated when there is sufficient brightness in the
area.
When motion is no longer detected, the sensor turns the light off after a
set time delay (Delayed-Off Time).
The walk-through feature is useful in areas that are momentarily
occupied, e.g. hallway. If the sensor detects no movement for more than
10 seconds light was turned off, it will apply a Delayed-Off Time of 2.5
minutes. If the sensor detects movement less than 10 seconds after light
was turned off, it will next turn the light off based upon the set time delay.
Brackets, screws and wall plugs for surface mount in solid ceiling
Spring clips for flush mount in drop ceiling
Infrared zone mask
Determine the number of sensors required to cover the floor area
Install the sensor near work area where walk-path cuts across radial
lines, not towards the sensor
Do not install the sensor near ventilation outlet
Avoid facing the ultrasonic transceivers to each other to minimize
interference
Prepare sensor mount. See illustration in the next page
Connect the sensor as shown in the wiring diagram. Make sure power
supply is turned off
Make sure there are no wiring exposed before mounting the sensor
Mount the sensor and turn on the power supply
Open the cover, review settings and change if necessary. See
Settings section
Initiate test mode, replace the cover and conduct walk-test
Toggle dip switch B3 (Off-On-Off) to enter test mode. If B3 is already in
the On position, moving it to the Off position will also activate test
mode
Amber LED will flash once every second when the sensor is in test
mode
During this time, the sensor will turn the light off after 5 seconds if
there are no movement
Test movement at entry point, walk path and occupancy area
Sensor will exit test mode after 15 minutes
LED indicator can be enabled or disabled by dip switch setting
Recommended for troubleshooting
Red LED indicates motion detected by infrared sensor
Green LED indicates motion detected by ultrasonic sensor
Operation
Initialization:
Detection and Activation:
Detection Sequence Logic
Sunset Sensor
De-Activation (Normal Occupancy Mode):
Walk-thru Mode:
Accessories:
Location:
Procedure:
Walk-Test:
LED Indicator:
Installation
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
0
m
m
2
2
0
4
4
2
2
4
4
PIR Optical View Pattern Ultrasonic Detection Pattern
CDL-608R12
Operation and Specification
SURE
N
©2011 SUREN Systems, Ltd.. All rights reserved. SUREN™
SUREN Part no.: N-ML00-0045-03-1
Rev.1
Printed in China
w w w . s u r e n s y s t e m s . c o m
Detection range
at 2.4m height
m
2
2
4
0
4
Power Supply:
Power Consumption:
Control Signal Output:
IR Sensor:
Ultrasonic Frequency:
12V DC (Power pack PS-112 or
PS-212 required)
0.96 W
12V DC, 15 mA
P
Pyroelectric 2-element
40 Khz
,
H
High-impact ABS
110mm Diameter x 56 mm Height
-40 to 55 C
20 V/m 10-1000 Mhz; 10 V/m 1-2 GHz
ousing Material:
Dimension:
Operating Temperature Range:
RF Immunity:
Approvals: