background image

Sure

Step

TM

 Stepping Systems User Manual

3–9

Chapter 3: 

Sure

Step

TM

 STP-DRV-4035 Microstepping Drive

5th Ed., Rev. B     01/2019

Using Logic That is Not 5 volt TTL Level

Some step and direction signals, especially those of PLCs, don’t use 5 volt logic. 
You can connect signal levels as high as 24 volts to the SureStep drive if you add 
external dropping resistors to the STEP, DIR and EN inputs, as shown below.

•  For 12 volt logic, add 820 ohm, 1/4 watt resistors
•  For 24 volt logic, use 2200 ohm, 1/4 watt resistors

Connecting to an Indexer with Sink or Source 12-24 VDC Outputs

Connecting to a PLC with Sink or Source 12-24 VDC Outputs

Note: Most PLCs can use 24 VDC Logic.

The Enable Input

The 

ENABLE

 input allows the user to turn off the current to the motor by providing 

a positive voltage between EN+ and EN-. The logic circuitry continues to operate, 
so the drive “remembers” the step position even when the amplifiers are disabled. 
However, the motor may move slightly when the current is removed depending on 
the exact motor and load characteristics.

Note: If you have no need to disable the amplifiers, you don’t need to connect anything 
to the 

ENABLE

 input.

Connecting to Indexer with 12 - 24 VDC Sinking Outputs - stretched

+12-24V

DIR+

DIR

DIR–

STEP+

STEP

STEP–

Indexer

with

Sinking

Outputs

R

R

STP-DRV-4035

Drive

EN+

EN–

R

ENABLE

(If enable function is used)

Connecting to PLC with 12 - 24 VDC Sinking Outputs - stretched

+12-24V

DIR+

DIR

DIR–

STEP+

STEP

STEP–

PLC

with

Sinking

Outputs

R

R

STP-DRV-4035

Drive

EN+

EN–

R

ENABLE

(If enable function is used)

+

COM

12-24 VDC

Connecting to Indexer with 12 - 24 VDC Sourcing Outputs - stretched

COM

DIR–

DIR

DIR+

STEP–

STEP

STEP+

Indexer

with

Sourcing

Outputs

R

R

STP-DRV-4035

Drive

EN–

EN+

R

ENABLE

(If enable function is used)

Connecting to PLC with 12 - 24 VDC Sourcing Outputs - stretched

COM

DIR–

DIR

DIR+

STEP–

STEP

STEP+

PLC

with

Sourcing

Outputs

R

R

STP-DRV-4035

Drive

EN–

EN+

R

ENABLE

(If enable function is used)

+

+12-24V

12-24 VDC

Summary of Contents for STP-DRV-4035

Page 1: ...Connection and Adjustment Locations 3 4 Connecting the Motor 3 5 Connecting the Power Supply 3 6 Connecting the Logic 3 7 Using Logic That is Not 5 volt TTL Level 3 9 The Enable Input 3 9 Setting Phas...

Page 2: ...ettings Optically isolated step direction and enable inputs Half 1 5 1 10 1 50 step switch selectable Automatic 50 idle current reduction can be switched off Block Diagram Optical Isolation Step V V S...

Page 3: ...Direction Signal Needs to change at least 2 microseconds before a step pulse is sent CW and CCW are viewed from the end opposite the drive end of the motor looking out of the shaft Enable Signal Logi...

Page 4: ...ctor STEP DIR EN Mounting Hole 1 of 6 Power Connector Motor Connector Switches for Selecting Current Step Resolution Current Reduction and Self Test Power On LED VDC STP DRV 4035 Step Motor Power Supp...

Page 5: ...P DRV 4035 microstepping drive Four Lead Motors Four lead motors can only be connected one way Please follow the wiring diagram shown to the right Note All AutomationDirect SureStep motors are four le...

Page 6: ...d information about choosing a different power supply please read the section titled Choosing a Power Supply in Chapter 7 SureStep System Power Supplies If your power supply does not have a fuse on th...

Page 7: ...into the drive signals a logic state to the phototransistors that are wired to the brains of the drive A schematic diagram input circuit is shown to the right You will need to supply a source of step...

Page 8: ...C N C Connecting to an Indexer with Sourcing Outputs Connecting to an Indexer with Sourcing Outputs COM DIR DIR DIR STEP STEP STEP Indexer with Sourcing Outputs STP DRV 4035 Drive EN EN N C N C Connec...

Page 9: ...e step position even when the amplifiers are disabled However the motor may move slightly when the current is removed depending on the exact motor and load characteristics Note If you have no need to...

Page 10: ...d 1 6 Each switch controls the amount of current in amperes A that its label indicates in addition to the minimum current value of 0 4 Amps There is always a base current of 0 4 Amps even with all fiv...

Page 11: ...PHASE 0 1 0 2 0 4 0 8 1 6 2 1 AMPS PHASE 0 1 0 2 0 4 0 8 1 6 2 2 AMPS PHASE 0 1 0 2 0 4 0 8 1 6 2 3 AMPS PHASE 0 1 0 2 0 4 0 8 1 6 2 4 AMPS PHASE 0 1 0 2 0 4 0 8 1 6 2 5 AMPS PHASE 0 1 0 2 0 4 0 8 1...

Page 12: ...ooth motion microstep drives can be used to provide motion in convenient units When the drive is set to 2 000 steps rev 1 10 step and used with a 5 pitch lead screw you get 0001 inches step Setting th...

Page 13: ...ch below Sliding the switch away from the 50 IDLE label disables the reduction feature Self Test The SureStep drive includes a self test feature This is used for trouble shooting If you are unsure abo...

Page 14: ...nk To operate the drive continuously at maximum power you must properly mount it on a heat sinking surface with a thermal constant of no more than 4 C Watt Often the metal enclosure of your system wil...

Page 15: ...15 Chapter 3 SureStepTM STP DRV 4035 Microstepping Drive 5th Ed Rev B 01 2019 Dimensions 3 00 76 2 0 125 3 2 4 00 101 6 2 50 63 5 3 75 95 3 3 70 94 0 1 50 38 1 0 875 22 2 0 15 3 8 0 25 6 4 0 25 6 4 D...

Page 16: ...Chapter 3 SureStepTM STP DRV 4035 Microstepping Drive SureStepTM Stepping Systems User Manual 3 16 5th Ed Rev B 01 2019 BLANK PAGE...

Reviews: