5.6.3 Hardware Monitor
To view the internal RAID controller’s hardware information, click the
Hardware Monitor
link from the
Information
menu. The Hardware Monitor Information screen appears.
The Hardware Monitor Information provides the temperature, fan speed (chassis fan) and voltage
levels of the SR-TRITON16Ni subsystem. All items are also unchangeable. When the threshold values
are surpassed, warning messages will be indicated through the LCD, LED and alarm buzzer. If you
have setup the SMTP, SNMP, syslog or messenger, you will also be notified as well.
Item
Warning Condition
Controller Board Temperature
> 70 Celsius
HDD Temperature
> 65 Celsius
Controller Fan Speed
< 1500 RPM
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.4V
Power 3.3V
< 3.0V or > 3.6V
DDR Supply V2.5V
< 2.25V or > 2.75V
CPU Core V1.3V
< 1.17V or > 1.43V
DDR Termination Power +1.25V
< 1.125V or > 1.375V