Chapter 6 System Maintenance
Internal RAID Controller
6.1 Upgrading the Internal RAID Controller’s Cache Memory
The internal RAID controller is equipped with one SDRAM socket. By default, the internal RAID controller
comes with 512MB of cache memory that is expandable to a maximum of 2GB. The expansion memory
module can be purchased from Partners Data Systems. Only Partners Data Systems approved cache
memory is supported.
6.1.1 Upgrading Memory Module
1. Shutdown the SR-TRITON16Ni system via the proNAS GUI and unplug all power cords.
2. Press the push button lock on the top cover of the chassis, and pull the top cover handle
towards the rear. Then remove the top cover.
3. Remove the cache memory module from the RAM socket of the internal RAID controller by
pressing the ejector clips until the memory module pops out of the socket.
4. Align the new memory module into the socket. Make sure the notch is aligned with the key on
the socket itself. With the ejector clips in open position, press down on the memory module
into the socket until fully into place. The ejector clips will automatically close to lock the
memory module. You will hear a clicking sound when fully seated.