iControl Manual                                                                                           

 

 

 

 
The dialog for each schedule type is similar. You must give the new schedule a unique name, 
which should be something that clearly says what this schedule will do. You then select the date 
and time at which to execute this scheduled event. The actions themselves are as follows: 

 
Change an Outlet

 is used to turn an outlet on or off. 

 

Run a Sequence

 will run a previously defined sequence. The names of the sequences in the 

drop-down box are the names they were given when they were created. A sequence must be 
created before a schedule can use it. 
 

Send an Email 

will send an email to a chosen recipient. The recipients showing in the drop-

down box must be created in Setup Email before a schedule can use them.  

*Please do not use special characters (<, >, #, etc.) in the email subject or body, or end the 
message body with a period (.).

 

 

To run a schedule to test it, click “Test”.  To delete a schedule, click “Delete”.  

 
Setup Page 

 

Date and Time 
 

This page allows the configuration of date and time settings. 
 

Automatic 

specifies that the iControl should automatically synchronize its time with an internet 

time server.  You may enter the address of a time server in the text box, or leave the default time 
server in place. 
 

Manual

 specifies that the iControl should maintain its own clock, starting at the date and time 

entered in the text boxes.  The format for the date is YYYY/MM/DD.  The format for the Hour is 
24-hour time (3pm = 15, etc.).  

*The use of Manual time is not recommended, especially for 

long-term scheduled events. The clock may drift, resulting in scheduled events not executing as 
expected.  Loss of power will result in the clock being reset.

 

 

Time Zone

 allows the selection of the time zone you are in. 

 

Adjust Clock for Daylight Savings Time

 specifies whether or not to automatically adjust the 

clock during Daylight Savings Time.

 

 
Email 
 

This page allows the setup of email information, including the mail server and email recipients. 

*Add the iControl to your allowed sender list to avoid emails from the iControl being sent to a 
junk folder, or blocked by a spam filter.

 

 

User Information

 specifies the return address for email messages sent from the iControl. 

Summary of Contents for iControl SX1115-iP

Page 1: ...USER MANUAL SurgeX SX1115 iP SX1120 iP Web Enabled Power Conditioning Management System V1 0 19...

Page 2: ...T UP 3 INSTALLATION 3 120 VOLT CONNECTIONS 3 TCP IP TELNET CONNECTION 4 TEMPERATURE SENSOR 4 LED INDICATORS 4 WEB SERVER 4 HOME PAGE 4 ACTIONS PAGE 5 SEQUENCES PAGE 7 SCHEDULES PAGE 7 SETUP PAGE 8 FRO...

Page 3: ...tacles 1 and 2 SurgeX ICE eliminates problems associated with inrush currents from large loads such as amplifiers With SurgeX ICE it is not necessary to take inrush currents into account when designin...

Page 4: ...ssing and holding the front panel reset button until the LEDs turn off approximately 1 second or by cycling power to the unit 7 Disconnect the network cables 8 Restore your computer s original IP sett...

Page 5: ...on is as follows SELF TEST Green When illuminated the surge suppression circuitry is functioning correctly POWER Red When illuminated the iControl is connected to a live wall or floor outlet OVER UNDE...

Page 6: ...es button Status displays the current outlet state On or Off Press Refresh after making changes to reload the web page with the current outlet states displayed Current Draw displays the true RMS curre...

Page 7: ...he Surge Protection Status maintains a Failed state after pressing Clear Shutdown the iControl will need to be returned to SurgeX for analysis and repair or replacement Press Clear Shutdown on the Set...

Page 8: ...ear in the Actions Page when a sequence is selected as an action There can be up to 20 steps in a single sequence Select the time delay from the Delay Time column Select the outlet from the Item To Ch...

Page 9: ...ate and time settings Automatic specifies that the iControl should automatically synchronize its time with an internet time server You may enter the address of a time server in the text box or leave t...

Page 10: ...ted as hyperlinks on the upper left side of all the web pages Click Add to open the Add a Favorite page Enter the other unit s name and IP address and press Save Network This page allows the configura...

Page 11: ...ely 1 second then release The system will then reboot System Restore to Factory Defaults Warning removes all configuration information including network setup email setup outlets setup sequences and s...

Page 12: ...gy Unlimited due to current limiting Endurance C62 41 1991 category B3 pulses 1 KV 500 000 3 KV 10 000 6 KV 1000 Undervoltage Shutdown Adjustable from 90 Volts to 105 Volts Overvoltage Shutdown Adjust...

Reviews: