25
The unit starts to sequence up but then immediately sequences down
This is most likely caused by a Down input that is on all the time and over-riding the power up
sequence.
The unit will not go into programming mode
You must power down the unit first before you can get into the programming mode.
8
Error Codes
Error codes are displayed on the third line of the display.
Error 05
The calibration of the AC voltmeter is no longer accurate. The unit is otherwise
fully operational. Call the factory for assistance.
Error 15
There is a checksum error in the non-volatile memory. This indicates that the set-
up information could be incorrect. It is recommended that you completely check
the programming and save the settings again. If error 15 is still displayed there is
most likely a permanent problem with the non-volatile memory.
Error 16
There is a sub-system error. The unit will need to be returned to the factory for
repair.
Error 24
Please call the factory.