XU115 Manual                                                                                                                                            

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XU115-510 

 
 

USB Communications Port Connection (optional) 
 

The Power Monitoring Software can be used with the UPS. Use the interface cable that comes with the UPS. 
Connect one end of the USB cable to the USB communications port on the rear panel of the UPS. Connect the 
other end of the USB cable to the device that will be monitoring/controlling the UPS. NOTE: Connecting to the 
communications port is optional. The UPS works properly without this connection. 
 
 

Phone/Fax/Modem/Network Protection Connection (optional) 

 

Connect a 10/100 Base-T network, single line phone, fax or modem line to the RJ-11/45 modular connectors on 
the rear panel of the UPS. This connection will require another length of telephone (provided) or network cable. 
The cable coming from the telephone service or network system is connected to the port marked “IN”. The 
equipment to be protected is connected to the port marked “OUT”. NOTE: Connection to the 
phone/fax/modem/network modular connectors is optional. The UPS work properly without this connection. 
 
 

OPERATION 

 

Charging The Battery 
 

The UPS will charge the internal batteries whenever the UPS is connected to an AC source and there is an 
acceptable AC voltage present (90-150VAC). It is recommended that the UPS’s batteries be charged for a 
minimum of 4 hours before use. The UPS may be used immediately; however, the “On Battery” runtime may be 
less than normally expected. NOTE: If the UPS is going to be out of service or stored for a prolonged period of 
time, the batteries must be recharged for at least 25 hours every ninety days. 
 

Turning The Unit On/Off 
 

Press and release the small black On/Off button on the front panel to turn the UPS on. The alarm will sound on 
beep and the LED’s will cycle while the UPS performs a five second internal self-test. Once the UPS has passed 
its internal self-test the UPS will provide an output and the load will be powered. Press and release the On/Off 
button to turn the UPS off. The UPS will continue to charge the batteries whenever it is plugged into a wall 
outlet and there is an acceptable AC voltage is present. 
 
 

USB Communications Port 
 

The USB communications protocol is HID. The HID USB driver comes standard in the Windows OS. Simply 
plug the USB cable into the UPS and the computer, then follow the prompts on the screen. 
 

Power Monitoring Software 
 

The UPS comes with power monitoring software. See the software CD for the installation of the power 
monitoring software. 
 

Summary of Contents for XU115

Page 1: ...XU115 510 USER MANUAL SurgeX XU115 Line Interactive 1000VA UPS with Automatic Voltage Regulation Surge Eliminator Power Conditioner...

Page 2: ...ING YOUR EQUIPMENT 2 USB COMMUNICATIONS PORT CONNECTION 3 PHONE FAX MODEM NETWORK PROTECTION CONNECTION 3 OPERATION 3 CHARGING THE BATTERY 3 TURNING THE UNIT ON OFF 3 USB COMMUNICATIONS PORT 3 POWER M...

Page 3: ...tion To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code ANSI NFPA 70 Plug the UP...

Page 4: ...PS is connected to an AC source and there is an acceptable AC voltage present 90 150VAC It is recommended that the UPS s batteries be charged for a minimum of 4 hours before use The UPS may be used im...

Page 5: ...seconds The alarm will stop once the UPS returns to the AC normal mode Low Battery Warning The UPS will sound two beeps every five seconds when the battery reserve runs low This condition will contin...

Page 6: ...he computer cable from the UPS and press the On button If UPS works normally the software has control of the UPS UPS does not provide expected runtime The batteries may be weak or at the end of useful...

Page 7: ...es and boots 4 Do not lay tools or other metal parts on top of the batteries 5 Disconnect the charging source prior to connecting or disconnecting the battery terminals 6 Determine if the battery is i...

Page 8: ...rload Capability 110 5 minutes 120 immediate shutdown Output Voltage Regulation 120VAC 12 5 to 8 4 Waveform Same as Input Boost Mode Voltage Buck mode voltage Nominal 16 Nominal 14 Line Mode Voltage R...

Page 9: ...nce C62 41 1991 Category B3 pulses 1kV 500 000 3 kV 10 000 6 kV 1000 General Specifications Warranty USA and Canada only 10 year limited warranty Battery Warranty 2 years Monitoring Software Includes...

Reviews: