3ZZX419340E-05  10/10 

 Notes on Warranty  

The warranty runs for one year after the day when Surpass Industry products are delivered from Surpass 
factory in Japan. In case Surpass Industry should agree in writing that the defects in performance or 
material were caused by faulty design or workmanship of Surpass Industry, replacement products will be 
supplied free of charge. This warranty shall not be applied to any defects caused by misuse, alteration, 
neglectful treatment, and neglect of our recommendations or instructions. 
In addition, we are not be liable to any direct or consequential loss, damage, and personal injury due to an 
unauthorized usage in combination with other products and an improper usage outside of the specifications. 
Our product warranty shall be limited to replacement of product. 
 
Replacement with expense to the purchaser shall be applied to the followings: 

  Any defective products caused by usage that is not described in the Instruction Manual. 

  Any defective products caused by neglectful treatment. 

  Any defective products caused by decomposition, alteration, and improper adjustment or repair. 

  Any defects of products caused by acts of God including natural disaster or fires. 

  Consumables and accessories. 

 
 
 

 

 

 

 

Surpass Industry Co., Ltd.

 

2203 Shimooshi, Gyoda-shi, Saitama 361-0037 Japan 

TEL: +81 48 554 9760      FAX: +81 48 554 9906 

URL: 

http://www.surpassindustry.co.jp

 

C  2012-2020 Surpass Industry Co.,Ltd. All rights reserved. 

Summary of Contents for HASP-SHT2

Page 1: ...3ZZX419340E 05 1 10 Fluorine Resin Type Pressure Sensor HASP SHT2 Operation Manual Surpass Industry Co Ltd 2020 5...

Page 2: ...nly within the specified operating environment Otherwise damage to the pressure sensor and connector may occur and result in liquid leakage The use of dangerous chemicals solvents and gases may cause...

Page 3: ...icable Fluid Liquids gases Linearity 1 F S at 25 C Hysteresis 1 F S at 25 C Temperature Effects 0 08 F S C Output Current DC 4 to 20 mA Voltage DC 1 to 5 V Power supply zero tracking output Max 30V 8...

Page 4: ...X419340E 05 4 10 Outer Dimensions Names and Functions on the Display Unit Cable Case Body Connector Air purge for OUT Air purge for IN LED lamp Lights up when power is supplied Flashes during zero adj...

Page 5: ...angerous chemicals solvents and gases may cause physical impairment Refrain from excessive tightening of the connector parts Otherwise damage to the pressure sensor and connector may occur and result...

Page 6: ...Never do wiring work when power supply is on Doing so may cause electrical shock Do not pull or bend the cable forcibly It may cause breakage of the cable electrical shock or fire In addition pulling...

Page 7: ...djust error If the zero adjust output keeps alternating ON OFF after at least three seconds from the time zero adjust started it is the indication of a zero adjust error When zero adjust is in progres...

Page 8: ...3ZZX419340E 05 8 10 Cable Removal Method Name of each part Cable remove method Cable installation method...

Page 9: ...by 1 F S or more Short circuit the zero tracking input for 1 or more second to reset the error Adjust the pressure in your piping so that it fluctuates less than 1 F S Then repeat zero adjust No anal...

Page 10: ...injury due to an unauthorized usage in combination with other products and an improper usage outside of the specifications Our product warranty shall be limited to replacement of product Replacement w...

Reviews: