Manual de usuario

cooling . If humidity is high, an air filter can be 
installed on the air outlet adapter to remove 
excessive moisture. Follow the instructions pac-
kaged with the air filter for proper installation. 

TO START & STOP THE COMPRESSOR
1. Check the rating label on the compressor in-
dicates 127 V.
2. Plug in the mains cable of the compressor to 
a standard 127 V household power point and 
turn on.
3. To start the compressor, lift the ON/OFF switch 
on the pressure switch cover.
4. To stop the compressor, push the ON/OFF 
switch down.

DUTY CYCLE
All Makita manufactured air compressors are re-
commended to be operated on not more than 
a 60% duty cycle. This means an air compressor 
that pumps air more than 60% of one hour is 
considered misuse because the air compressor is 
undersized for the required air demand .

OPERATION

1. The pressure in the tank is controlled by the 
action of the pressure switch located under   the 
pressure switch cover. When the set maximum 
pressure is reached the pressure switch activates 
and the motor is switched off. 
The pressure then decreases as the air is used by 
the connected tool until the set minimum pres-
sure is reached after which the pressure switch 
causes the motor to switch on again.
The operator of the compressor should be well 
aware that during use of the compressor the 
motor will start and stop under the influence 
of the rising or falling pressure in the tank. The 
motor will start without any warning. 
2. The maximum and minimum pressures are 
factory set and the operator should not try to 
change them.
3. All accessories are connected to the regulated 
outlet valve.
4. The pressure of the regulated outlet, as 
shown on the regulated outlet pressure gauge, 
can be changed by turning the regulating knob.
NOTE: to obtain the correct output reading  on 
the regulated output gauge, the air must be 
flowing through the outlet.
The regulating valve should be adjusted and the 
gauge read with the outlet valve open and the 
air being discharged from the regulated outlet 
through the accessory being used.
To increase the air pressure, rotate the regulat-
ing valve clockwise. To decrease the pressure, 
rotate the regulating valve anti-clockwise.
NOTE: if you do not allow the air to discharge 

while you are setting the regulator, the pressure 
as indicated on the regulated outlet gauge will 
be incorrect. This gauge ONLY indicates the cor-
rect pressure while air is being discharged from 
the outlet.
5. On completion of the task, i.e. when you have 
finished using the compressor, or when you are 
leaving the compressor unattended, turn off the 
compressor in the following way:
• Press down the on/off switch.
• Wait for the pressurised air to bleed from the 
release valve under the pressure switch cover.
NOTE: when you press the button down you 
should hear a short air discharge (approximately 
1/2 second).
• Switch off the electrical power supply and re-
move the electrical plug.
• Pull the ring (Fig.11) on the safety valve to en-
sure all the pressurised air is released from the 
tank, or open the drain cock to release the pres-
sure from the tank.

ADDITIONAL WARNINGS

1. Never attempt to remove any part of the com-
pressor whilst the tank is under pressure.
2. Never attempt to remove any electrical com-
ponent whilst the compressor is connected to 
the power supply. Switch off the power and re-
move the electrical plug.
3. Do not adjust the safety valve.
4. Do not use an electrical extension cable.
5. If the release valve under the pressure switch 
cover fails to operate when the on/off button is 
pressed down, switch the power supply off and 
determine the nature of the fault.
6. Ensure that the lubricating oil is clean and 
that the oil level is maintained at the mid point 
of the red circle in the oil level glass.
7. Take care when discharging air from the tank, 
i.e. from the safety valve, the drain cock or the 
air outlet. 
Compressed air can be extremely dangerous. 
Take care the discharge air does not cause dust, 
stones or any other foreign particles to be blown 
through the air and that the air is discharged in 
a safe manner.

MAINTENANCE

 WARNING: UNIT CYCLES AUTOMATICALLY 

WHEN POWER IS ON. WHEN DOING MAINTE-
NANCE, YOU MAY BE EXPOSED TO VOLTAGE 
SOURCES, COMPRESSED AIR OR MOVING PARTS. 
PERSONAL INJURIES CAN OCCUR. BEFORE PER-
FORMING ANY MAINTENANCE OR REPAIR, UN-
PLUG THE COMPRESSOR AND BLEED OFF ALL 
AIR PRESSURE.

Summary of Contents for COMP410

Page 1: ...ual antes de operar esta herramienta WARNING read understand and follow the safety rules in this manual before operating this tool COMP410 COMP425B COMP6100 COMP6200 COMP550B COMP425K COMP6120V COMPRE...

Page 2: ...s de seguridad para compresores de aire Caracter sticas Especificaciones t cnicas Instrucciones de operaci n Mantenimiento Solucionador de problemas Notas Garant a 11 11 11 12 12 13 13 14 15 17 18 20...

Page 3: ...entre en la herramienta aumentar el riesgo de choque el ctrico No abuse del cable No usar nunca el cable para llevar levantar o desenchufar la herramienta el ctrica Mantenga el cable lejos del calor a...

Page 4: ...ramienta el ctrica si el interruptor no acciona encendido y apagado Cualquier herramienta el ctrica que no pueda controlarse con el interruptor es peligrosa y debe repararse Desconecte la clavija de l...

Page 5: ...ctar y antes de encender no exista alguna parte suelta o sobre el compresor Aseg rese de leer todas las etiquetas en los contenedores pinturas u otros materiales para ser rociados Estrechamente siga t...

Page 6: ...UDAL M XIMO 224 L min 7 9 CFM PRESI N M XIMA 115 PSI VELOCIDAD EN VAC O 3 450 r min POTENCIA 2 HP HORAS DE USO M XIMO 6 horas NIVEL DE RUIDO 88 dB TEMPERATURA DE TRABAJO 85 C 90 C PESO 21 4 kg 47 1 lb...

Page 7: ...udie ran intervenir con el flujo de aire El cabezal y la cubierta del compresor de aire est n dise ados para permitir el correcto enfriamiento Si la hu medad es alta puede instalar un filtro de aire e...

Page 8: ...NTO ADVERTENCIA LA UNIDAD REALIZA CICLOS AUTOM TICAMENTE CUANDO SE LE SUMINIS TRA ENERG A CUANDO REALICE MANTENI MIENTO PODR A ESTAR EXPUESTO A FUENTES DE VOLTAJE AIRE COMPRIMIDO O PARTES M VILES PODR...

Page 9: ...oque el tubo de liberaci n de presi n y accesorios 9 Coloque el tubo de escape y apriete las tuer cas superior e inferior 10 Coloque la cubierta MOTOR El motor tiene un interruptor manual de pro tecci...

Page 10: ...a una salida el ctrica Verifique y remplace si es necesario Remueva y limpie o remplace Ajuste los accesorios Vea la secci n de Gu a de Soluci n de Problemas de Fugas de Aire EL MOTOR NO TRABAJA Caus...

Page 11: ...s should be used to prevent excessive voltage drop loss of power or overheating The table below shows the cor rect size to use depending on cord length and nameplate amperage rating of tools In case o...

Page 12: ...pment is not permitted Explosive combustible gases or gases detrimen tal to health may not be compressed Opera tion in hazardous locations is not permitted Any other use is not a as specified alterati...

Page 13: ...plug Do not use the compressor without first check ing the oil level It must be close to the red circle as viewed on the oil gauge NOTE the compressor is supplied without oil It must be filled before...

Page 14: ...ompressor operation Immediately upon arrival check equipment for both concealed and visible damages to avoid ex penses being incurred to correct such problems This should be done regardless of any vis...

Page 15: ...air pressure rotate the regulat ing valve clockwise To decrease the pressure rotate the regulating valve anti clockwise NOTE if you do not allow the air to discharge while you are setting the regulato...

Page 16: ...80 6 F SAE 30W ISO 100 SERVICE INSTRUCTIONS Air Filter Inspection and Replacement Keep the air filter clean at all times Do not ope rate the compressor with the air filter removed A dirty air filter...

Page 17: ...op when the accessory is used adjust the regulator following the instruc tions NOTE Adjust the regulated pressure under flow conditions while accessory is being used AIR LEAK FROM SAFETY VALVE Cause P...

Page 18: ...heck for low voltage conditions and or pro per extension cord 3 Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Bleed the line by pushing th...

Page 19: ...19 E N G L I S H User s Manual Notas Notes...

Page 20: ...dified by unauthorized or unqualified person URREA HERRAMIENTAS PROFESIONALES S A DE C V garantiza este producto por el termino de 1 a o en sus piezas componentes y mano de obra contra cualquier defec...

Reviews: