Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-1
Page 7- 34
Rev: 1
Date: JAN 18
Prepared by: LA
Checked by : CLS
7.26 Rejected Landing
No visual cues/references at MAP
orApproach not stabilized
PF/PM:
“GO AROUND”
PF
call sfor go-around power,
max continuous power, and
rotates the aircraft 8° to 10°
attitude pitch.
PF Commences the missed approach
and calls
PF:
“GOING AROUND,SETPOWER,
FLAPS 18”
PM:
“POWER SET, FLAPS 18”
PF
calls for go around power.
PM
sets power and flaps as
required for the go around
procedure.
Set the flap and check instruments for
positive climb rate
PM: “
POSITIVE RATE”
PF:
“GEAR UP”
PM: “
GEAR UP SELECTED, GEAR
UP, lights out”
Call made by
PM
,
PFcrosschecks positive rate of
climb and call for gear up.
Above 400 feet and 100 KIAS, raise the
flaps
PF:
“Flaps up”
PM:
“Flaps up selected”
Flap retraction at
PF
command.
When the flaps are indicating up
PM:
“Flaps up indicated”
PM
selects flap as instructed.
Once the flaps are up while
accelerating to
120 KIAS, engage the Yaw Damper.
PF:
“Engage yaw damper”
PM:
“Yaw damper engaged”
Called by
PF.
Above 1000 ft AGL
PF:
“Set climb power”
Called by
PF.
After climb power set call, PM will
reduce TCLs to 80% torque and
propeller levers to 1,900 Rpm and
then reset TCLs to climb power
setting 98% Ng.
PM:
“Climb power set”
PM
sets power as instructed.
At 1500 ft AGL, accelerate to 130/145
KIAS and complete
the“After take-off checklist”.
PF:
“After take-off checklist”
PM:
“After t/o checklist
complete”
Called by
PF.
Summary of Contents for L410 UVP-E20