Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-0
PageDD -2
Rev: 1
Date:NOV 18
Prepared by: L.A.
Checked by: C.L.S.
TCL of the other engine
...............................................................
back to IDLE
On the test panel of the left control panel:
PROP FEATHERING AUTObutton
....................................................
release
On the overhead panel
PROP FEATHERING
circuit breaker.................................
switch OFF and back ON
AUT. BANK CONTROL
circuit breaker .............................
switch OFF and back ON
On the central control panel:
EMERGENCY THROTTLE LEVER
........................................................
OPEN
(if this lever has been used in the procedure)
NOTE
Use the same procedure to check the automatic feathering system of the other engine.