Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-0
Page EE - 22
Rev: 1
Date:JAN 18
Prepared by: LA
Checked by : CLS
ENGINE FAILURE DURING TAKE-OFF (AT SPEED > V1) FLAPS 0°
EC 6
Item
Action
CM
>
TCL of both engines
check TAKE OFF RATING
PM
>
FAILED ENGINE
DETERMINE
BOTH
After lift off:
>
LANDING GEAR
UP
PM
>
FAILED ENGINE PROPELLER
FEATHERING
CHECK
PM
(a) If the automatic feathering cycle has not been
accomplished:
>
MANUAL FEATHER. push-button of the
inoperative engine
PUSH
PM
>
ELU (LH + RH) circuit breakers
OFF
PM
(b) If the inoperative engine propeller has not been feathered even after
above measures had been taken then:
>
PCL of the inoperative engine
FEATHER
PM
AIRSPEED
min. V2, FLAPS 0
PF
AUT. BANK CONTROL switch
OFF
PM
At height of 400 ft (120 m) above RWY
TAKE OFF RATING
PM
INCREASE THE AIRSPEED
V2, FLAPS 0
PF
TCL of operating engine
set continuous OEI rating
PM
Summary of Contents for L410 UVP-E20