Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-0
Page EE - 23
Rev: 1
Date:JAN 18
Prepared by: LA
Checked by : CLS
AIRSPEED
V2 0 up to 1,500 ft (457 m)
above runway
PM
INOPERATIVE ENGINE
CHECK PARAMETERS
PM
(a) If the engine is fully stopped
The following items are valid for inoperative engine:
TCL
IDLE
PM
FUEL STOP COCK/ EMERGENCY
THROTTLE LEVER
SHUT
PM
GENERATOR DC + AC switches
OFF
PM
ENGINE STARTING, ELU, FUEL PUMP
CIRCUIT BREAKERS
OFF
PM
(b) If the engine operates at idle and other parameters correspond to
idle power then:
PROPELLER
UNFEATHER
PM
USE of emergency fuel control circuit
PM