Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-0
Page EE - 25
Rev: 1
Date:JAN 18
Prepared by: LA
Checked by : CLS
TCL of operating engine
set continuous OEI rating
PM
AIRSPEED
V2 0 up to 1,500 ft (457 m)
above runway
PM
Accomplish the following procedures for inoperative engine:
TCL
IDLE
PM
FUEL STOP COCK
SHUT
PM
GENERATOR DC + AC switches
OFF
PM
OFF
ENGINE STARTING, ELU,
FUEL PUMP CIRCUIT BREAKERS
8 PM