Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-0
Page EE - 55
Rev: 1
Date:JAN 18
Prepared by: LA
Checked by : CLS
ENGINE SHUTDOWN IN FLIGHT
AB 4
Item
Action
CM
TCL of operating engine
set continuous OEI rating or
lower, as required
PM
Procedure on the controls of the opposite engine to be shutdown:
TCL
IDLE
PM
MANUAL FEATHER. push-button
PUSH
PM
FUEL STOP COCK/ EMERGENCY
THROTTLE LEVER
SHUT
PM
GENERATOR DC + AC switches
OFF
PM
After the gas generator has stopped:
OFF
ENGINE STARTING, ELU, FUEL PUMP
CIRCUIT BREAKERS
PM
PCL
FEATHER
PM
Summary of Contents for L410 UVP-E20