Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-0
Page EE - 61
Rev: 1
Date:JAN 18
Prepared by: LA
Checked by : CLS
USE OF EMERGENCY FUEL CONTROL CIRCUIT
AB 11
Item
Action
CM
TCL
IDLE
PM
ISOLATION VALVE
ON
PM
AMBER ISOLATION VALVE
LIGHT
CHECKED ON
BOTH
FUEL STOP COCK/ EMERGENCY
THROTTLE LEVER
move slowly
forward from OPEN to the
emergency circuit
area
PM