Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-0
Page EE - 72
Rev: 1
Date:JAN 18
Prepared by: LA
Checked by : CLS
EMERGENCY EXTENSION OF LANDING GEAR
AB 24
Item
Action
CM
LANDING GEAR lever
DOWN
PM
LANDING GEAR
EMERGENCY EXTENSION lever
DOWN
CM 2
EMERGENCY HYDRAULIC PUMP
Pump until the 3 green lights
on landing
gear position indicator come
on and until resistance on
pump handle increases.
CM 2
If after the use of the emergency hydraulic pump some of the landing gear legs are stuck
in any intermediate position:
INCREASE AIRSPEED
135 KIAS
PF
CLIMB
SAFE ALT
PF
WAIT
60 SEC.
PF
SIDESLIP
PERFORM
PF
If locking of the landing gear leg does not take place:
SIDESLIP
REPEAT 3 TIMES
PF
After repeating the sideslip without result:
AIRPLANE SWINGING WITH BANK OF 30°
TO 45°
PERFORM MAX 8 TIMES
PF