Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-0
Page EE - 78
Rev: 1
Date:JAN 18
Prepared by: LA
Checked by : CLS
STATIC HEAD FAILURE
AB 32
Item
Action
CM
STATIC PRESSURE I AND II
CHECK ON
CM 2
(the green lights in these push
buttons must stay on)
If the LH INSTRUMENTS are affected:
EMERGENCY STATIC
PRESSURE red cock
OPEN
CM 1
If the RH INSTRUMENTS are affected:
AUTOPILOT
DISCONNECT
PF
Continue the flight without any special measures, but disregard
reading of the vertical speed indicator
on the RH instrument panel.