Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-1
Page 4 - 11
Rev: 1
Date: JAN 18
Prepared by: LA
Checked by: CLS
GPU ENGINE START
Condition
CM1
CM2
Check voltage
Verify External Power on
CWD is on.
VA selector set to
emergency bus, check
voltage
Voltage of the GPU (unloaded) between 27-29V / minimum 20 V
Before start checklist complete, ook out
and check prop clear
Check prop area clear
Check prop area clear
After engine start approval, Selecting
engine switch
Announce:Starting N°1/2
Push starter and hold for 3
sec
Start timing, check normal
Voltage
atillumination of engine starting cell
Announce: “Starter ON”
Monitor
atillumination of limiter active cell
Announce: ”Limiter Active”
Monitor
At first indication of oil pressure on selected
engines oil pressure gauge
Announce: ”Oil pressure
rising”
Monitor
At first indication of Ng
Announce: ”Ng rising”
Monitor
At first indication of fuel flow
Announce: ”Fuel flow”
Monitor
Call max ITT during start and
Announce: ”ITT….”
Take a note on the OFP
At first indication of Hydraulic pressure
Monitor
Monitor
As engines OIL PRESSURE cell extinguishes
Monitor
Announce: “Oil pressure
extinguished”
As engine starting cell extinguishes
Monitor
Announce: “Engine Starting
disconnected”
Captain checks idle engine parameters
normal
Announce: “Stable start”
Check