Standard Operating Procedures
L410 UVP-E20
Document No.:
SOP-L410-1
Page 4 - 12
Rev: 1
Date: JAN 18
Prepared by: LA
Checked by: CLS
General start callouts
StartCallouts
Lookoutandcheckpropclear
CAPT:
“Clear(No1/2)”
FO:
“Clear(No1/2)”
Selectingengineswitch
CAPT:
“Starting(No1/2)”
atillumination of engine starting cell
CAPT:
“Engine Starting”
atillumination of limiter active cell
CAPT:
“Limiter Active”
Whenvoltsdrop
FO:
“Voltdrop….v”
At first indication of oil pressure on selected engines oil
pressure gauge
CAPT:
“Oil pressure rising”
At first indication of Ng
CAPT:
“Ng rising”
At first indication of fuel flow
CAPT:
“Fuel flow”
Call max ITT during start and note on the OFP
CAPT:
“ITT….”
At first indication of Hydraulic pressure
CAPT:
“Hydraulic pressure”
As engines OIL PRESSURE cell extinguishes
FO:
“Oil pressure extinguished”
As engine starting cell extinguishes
FO:
“Engine Starting disconnected”
Captain checks idle engine parameters normal
CAPT:
“Stable start”