Installation, Operation & Maintenance Manual
The information contained in this section is intended to aid qualified service personnel in the testing and repair
of steambath generators.
To avoid electric shock, disconnect generator from electric voltage supply.
All servicing must be performed by qualified personnel only.
_______________________________________________________________________
Problem
Probable Cause
Suggested Remedy
_______________________________________________________________________
System is not working
Electric power is off
Turn power on or check circuit breaker
_______________________________________________________
Control is “OFF” or in “PAUSE” mode Turn control “ON”
_______________________________________________________
Temperature control is set too low
Set control to higher temperature
_______________________________________________________
System is heating up
Wait 5 minutes for steam
_______________________________________________________________________
NOTE:
The following servicing information is intended for use by qualified personnel
only. It is not intended for the home owner and/or end-user of this equipment. If there is
any question, consult with qualified personnel or the manufacturer.
_______________________________________________________________________
Problem
Probable Cause
Suggested Remedy
_______________________________________________________________________
System is not working
Improper installation
Review instructions
_______________________________________________________
Incorrect power supply
Check power supply
_______________________________________________________
Transformer malfunction
Check transformer output*
Replace, if necessary
_______________________________________________________
Control is inoperative
Check control operation*
Replace, if necessary
_______________________________________________________
Water is not feeding
See below
_______________________________________________________
Unit is not heating
See below
_______________________________________________________
Water is not feeding
Supply valve is closed
Open Valve
_______________________________________________________________________
Clogged water line
Check water line
_______________________________________________________
Low water pressure
Water pressure must be at least 10 psig
_______________________________________________________
Clogged solenoid valve built-in filter
Remove obstruction
_______________________________________________________
Probe is shorted to ground
Check for shorts
_______________________________________________________
Liquid level control board malfunction Check water solenoid operation*
_______________________________________________________
Solenoid valve malfunction
Check valve - Replace if necessary
_______________________________________________________________________
*See Major Electrical Components Test (page 12)
Trouble Shooting
13
!
WARNING
!
WARNING