Problem
Probable Cause
Suggested Remedy
_________________________________________________________________________
Unit is not heating
Drain valve is open
Close drain valve - Check for leaks
_________________________________________________________
Unit is flooding
See below
_________________________________________________________
Liquid level control malfunction
Check liquid level control for contactor operation*
_________________________________________________________
Burnt out fuse(s)
Check Fuses
_________________________________________________________
Contactor malfunction
Check contactor operation
_________________________________________________________
Heating element Malfunction
Check heating element
_________________________________________________________________________
Flooding
Loose probe connection
Check probe connection
_________________________________________________________
Liquid level control malfunction
Check probe operation
_________________________________________________________
Solenoid valve malfunction
Check valve
_________________________________________________________
Drain is backing up
Check drain plumbing
_________________________________________________________
Too much water in steam
See below
_________________________________________________________________________
Too much water
There is a valley (trap) in steam line
Check plumbing
_________________________________________________________
Steam line is not insulated
Insulate steam line
_________________________________________________________
Steam line is over 50 feet
Relocate steam generator closer to steam room
_________________________________________________________________________
Not enough steam
Unit is undersized
Check sizing
_________________________________________________________
Voltage is insufficient
Check power supply
_________________________________________________________
Heating element malfunction
Check heating element
_________________________________________________________
Leak in steam line
Check steam line
Use only brass pipe or copper tubing
_________________________________________________________
Steam is intermittent
See below
_________________________________________________________________________
Steam is intermittent
Temperature control is set too low
Control turns steam on and off at set temperature
- Turn control higher, as desired
_________________________________________________________
There is a valley (trap) in steam line,
Correct pitch of steam line
allowing water to block flow of steam
_________________________________________________________
Loose electrical connection
Check wiring
_________________________________________________________
Drain is leaking
Check drain valve
_________________________________________________________
Safety valve or tank is leaking
See next page
________________________________________________________________________
*See Major Electric Component Test (page 12)
Trouble Shooting
14
(water continuously
flows out of steam head)
in steam
(not hot enough)