Installation, Operation & Maintenance Manual
_________________________________________________________________________
Problem
Probable Cause
Suggested Remedy
_________________________________________________________________________
Too much steam (too hot)
Unit is oversized
Add room temperature control
or air switch
___________________________________________________
Temperature control is set too high
Set control to lower temperature
_________________________________________________________________________
Fuse blows out or
Fuse or circuit breaker is undersized
Check current rating
___________________________________________________
Over voltage (current)
Check voltage (current)
___________________________________________________
Short circuit
Check wiring
___________________________________________________
Heating element malfunction
Check heating element
_________________________________________________________________________
Heating element burns out
Over voltage
Check voltage
___________________________________________________
Incoming power connected
Check connections (see page 7)
directly to elements
___________________________________________________
Liquid level control malfunction
Check probe and contactor operation*
___________________________________________________
Probe shorted to ground
Check probe circuit
___________________________________________________
Loose electrical connection
Check wiring
___________________________________________________
Contactor malfunction
Check contactor*
___________________________________________________
Too much calcium build-up on element Flush generator after each use
_________________________________________________________________________
Water continuously flowing
Drain left in open position
Close drain
out of drain line
___________________________________________________
If AutoFlush - malfunction
Check circuit board
of circuit board
___________________________________________________
If AutoFlush- AutoFlush valve
Clean or replace valve
obstructed by calcium build-up
*See Major Electrical Components Test (page 12)
Trouble Shooting
15
circuit breaker trips