Mr
S
team
Installation, Operation & Maintenance Manual
Read these instructions before installation or service. Although this MS steambath generator has been fully quali-
fied for shipment by MR. STEAM, the following must be reviewed for proper, safe and enjoyable steam bathing.
Verify that the model and accessories are correct, including incoming line voltage.
Insure steambath generator has been correctly sized for the steambath room. Pay particular attention to room
volume and construction. If any questions, please refer to MR. STEAM sizing guide enclosed. (see page 16)
Marble or glass walls or ceilings, or exterior walls “ENLARGE” the room’s size, requiring a generator larger
than one based only on the room’s cubic foot (L x H x W) volume.
The physical size of the unit, clearance for plumbing servicing, and its distance from the steam room must all
be considered before final installation.
IMPORTANT
MR. STEAM units are intended to be operated with a MR. STEAM timer and/or temperature control only,
and are to be installed strictly in accordance with the specific instructions supplied with these optional
accessories and the information contained in this manual.
Mr. Steam steam generators are connected to 240V line voltage and contain live electrical components. All instal-
lation and service to be performed by qualified electricians and plumbers only. Installation or service by unquali-
fied persons may void the warranty.
1.
Steam room must be completely enclosed, with full walls, door, floor and ceiling.
2.
It is recommended that a gasketed door is used for heat sealing and steam containment.
3.
If tile-type flooring is used, install anti-skid strips or equivalent, for safety.
4.
Walls and ceilings must be covered with water-resistant, non-corrosive surface,
such as tile, molded acrylic, fiberglass, etc.
5.
Provide a floor drain.
6.
No heating, venting or air conditioning devices should be installed inside the steam room.
Before Installing
1
Steam Room Requirements
!
WARNING