Mr
S
team
Installation, Operation & Maintenance Manual
Select a location as near as possible to the steam room.
Typical locations include: closet, vanity cabinet, heated attic or basement.
1.
Locate steambath generator within 25 feet of steam room.
2.
Do not install steambath generator inside steam room.
3.
Do not install steambath generator outdoors.
4.
Do not install steambath generator in unheated attic or any locations where water could freeze.
5.
Do not install steambath generator near combustible or corrosive materials and chemicals.
6.
Install steambath generator on a solid and level surface.
7.
Install steambath generator in an upright position only.
8.
Install anti-water hammer device as required.
9.
Provide access to both ends of steambath generator for servicing. See page 5.
10.
Steam line, safety valve and drain valve become hot during operation. Provide appropriate protection.
11.
MR. STEAM CONTROLS can be located inside the steam room or on the outside of the steam room.
See separate CONTROL INSTALLATION AND OPERATION INSTRUCTIONS for specific details.
If the SMART/TWO or SMART/PLUS controls are located outside the steamroom, a remote sensor (part
number MSNC) is required.
NOTE:
The SMART/ONE, SMART/REMOTE, SMART/TWO and SMART/PLUS controls are
UL Approved for installation and operation in a wet location
Locating the Steam Generator Unit
Typical MrSteam Installation
Locate control
4 to 5 feet above floor
Locate steamhead
6"-12" above floor
Power supply
Mr. Steam
steam generator
Safety valve
Control cable
Steam room enclosure
Steam line
Drain
Steam head
Water feed
2