Sutron Corporation X-Link Operations & Maintenance Manual, Rev 1.63 5/24/2016 pg. 115
The downloaded data is in Sutron Standard CSV format and can be easily
displayed using Sutron’s GRAPHER program (downloadable from
www.sutron.com
) or common spreadsheet/word processing programs.
You can download the whole log or only parts of it. You may specify the start
date and optionally the end date for the downloaded data. You may also ask for
data from the last X days.
There are options to download only data from a specific measurement. Events
can be excluded form the log download.
X-Link remembers the last log download and will allow downloads since last
download. This means that the only parts of the log downloaded are those that
have not been previously downloaded.
9.2.
Log Events
Occasionally, X-Link will log events. Events are used to help troubleshoot the
data.
The following actions will cause the X-Link to log an event:
Setup change (when any setting is changed)
Log download (when the log is downloaded)
Reset (log contains reset type and count)
Errors (such as low battery and sensor failure)
Before cal and after cal (logged when the user sets the sensor level to record
the value before and after the calibration)
Log in events (if password is enabled), including failure to log in.
Telemetry events (transmission made, message received, etc.)
Alarm events
The setting
Log Daily Values
determines whether certain log events are logged
every day before midnight.
Here is a list of some of the log events and their descriptions: