Interfaces of the Device
P Line Touch Panel
54
4.4.1.1
Pin Assignment
Figure 4-8 5 pin M12 male connector
Connector in the operating device: 5 pin M12 male connector.
4.4.1.2
Cable
The maximum cable length depends on the data transfer rate used.
Table 4-9 Pin assignment CAN 1
Pin
Designation
Function
1
PE
Shielding
2
Reserved
Reserved for DeviceNet
3
CAN1_GND
CAN Ground
4
CAN1_H
CAN_H Bus Line
5
CAN1_L
CAN_L Bus Line
Table 4-10 Pin assignment CAN 2
Pin
Designation
Function
1
PE
Shielding
2
Reserved
Reserved for DeviceNet
3
CAN2_GND
CAN Ground
4
CAN2_H
CAN_H Bus Line
5
CAN2_L
CAN_L Bus Line
NOTICE
The M12 connectors must be connected to the cable shield.
NOTICE
A shielded twisted-pair cable complying with ISO 11898-2 must be used.
A suitable cable with the designation „SAC-5P- 2,0-920/FS SCO“ is offerd by
Phoenix Contact GmbH with article number 1518216.
Table 4-11 Bit rate CAN
Bit rate
Cable length
125 kBit/s
500 m
500 kBit/s
100 m
1 MBit/s
40 m
Summary of Contents for P Line