Bringing the Benefits of Real-Time Data Collection to the World
Sutron Corporation, Tel: 703-406-2800,
http://www.sutron.com
179
Com Port and RS-485
Use the
Com Port
property to select the port on which you’ve connected the PB200/200WX
sensor. If you’ve connected the sensor to an RS485 port, then check the
RS-485
option (note,
COM4 and COM6-COM9 are available as RS485 by factory option on the Xpert).
Power Control
The
PwrCtrl
,
Module
, and
Channel
properties control when and how the sensor is powered.
Power to the sensor can either be switched or constant. The following table describes
connections and behavior for the different values of
PwrCtrl
:
PwrCtrl
Connections and Behavior
AIO SW12
Connect sensor V+ to the SWBATT terminal of a connected AIO module.
Set the Module property to the number of the connected module.
DIO SW12
Connect sensor V+ to the SWBATT terminal of a connected DIO module.
Set the Module property to the number of the connected module.
DIO CHAN
This option is used when connecting sensor power to an external relay
controlled by an Xpert digital output channel. Connect sensor V+ to the
power supply terminal of the relay. Connect the relay control signal to the
DIO module output channel. Set the Module property to the number of the
DIO module. Set Channel to the number of the output channel controlling
the relay.
PROT 12
Connect sensor V+ to a connector that provides constant 12V
Warmup (s)
The PB200/200WX takes several seconds following power-on before valid data is produced. The
Warmup property is used to define how long to wait before attempting to read data from the
Summary of Contents for Xpert2
Page 2: ......
Page 11: ...Chapter 1 Introduction...
Page 16: ......
Page 17: ...Chapter 2 Getting Started...
Page 86: ......
Page 87: ...Chapter 4 Graphical Setup Diagrams...
Page 104: ......
Page 105: ...CHAPTER 5 EXAMPLE SETUPS...
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ...Chapter 7 Installation...
Page 140: ......
Page 141: ...Chapter 8 Maintenance and Troubleshooting...
Page 145: ...Appendix A Setup Blocks...
Page 266: ......
Page 267: ...Appendix B Updating the Firmware...
Page 290: ......
Page 291: ...Appendix E Software Development Kit SDK...
Page 293: ...Appendix F Creating Custom Voice Files...
Page 330: ......