SE8500 (SE8500)
Inputs
<none>
Outputs
Output
Wiring
The SE8500 can connect to any of the Xpert serial ports. The SE8500 wires to the 6461-1239
termination board as follows:
Color
Name
Pin (6461-1239)
Red
+12
6
BLK
GND
5
White
TXD
3
Green
RXD
2
Description
This block measures a SE8500 configured for serial output. It can also work with an SE8500
connected to a wireless link. The properties allow setting the Com Port, range, offset, address
and units.
NOTE:
Leave the settings in the SETUP TAB/ COMS (SSP/CL) set to none, as this
block will not be able to use the com port if Coms (SSP/CL) is already using it. Address
specifies which address the SE8500 is set to. Typically address is 0. Other valid addresses are
1..9, A..F.
After the value is read from the SE8500 it is scaled as follows:
Value = reading * range + offset.
Range is typically 0.01 because the SE8500 multiples its value by 100 before sending it.
However, you can select a different range value if desired.
Summary of Contents for Xpert2
Page 2: ......
Page 11: ...Chapter 1 Introduction...
Page 16: ......
Page 17: ...Chapter 2 Getting Started...
Page 86: ......
Page 87: ...Chapter 4 Graphical Setup Diagrams...
Page 104: ......
Page 105: ...CHAPTER 5 EXAMPLE SETUPS...
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ...Chapter 7 Installation...
Page 140: ......
Page 141: ...Chapter 8 Maintenance and Troubleshooting...
Page 145: ...Appendix A Setup Blocks...
Page 266: ......
Page 267: ...Appendix B Updating the Firmware...
Page 290: ......
Page 291: ...Appendix E Software Development Kit SDK...
Page 293: ...Appendix F Creating Custom Voice Files...
Page 330: ......