Bringing the Benefits of Real-Time Data Collection to the World
Sutron Corporation, Tel: 703-406-2800,
http://www.sutron.com
210
Specifically, the
Schedule Interval
indicates how often the DQAP block should sample a series
of data points, process them, and output values. The
Schedule Time
specifies the
synchronization of when this should begin. The
Sample Interval
entry indicates how often the
sensor should be sampled each time its scheduled to sample and the
Sample Duration
specifies
for how long. To average continuously, the
Schedule Interval
should be set equal to the
Sample
Duration
.
Summary of Contents for Xpert2