System Commissioning and Application Example NICE3000
new
User Manual
- 98 -
When two elevators are in parallel mode, the addresses of the HCBs should be set
according to physical floors. Parallel running can be implemented only when the HCB
address set for one elevator is the same as that for the other elevator in terms of the same
floor.
Note
In parallel mode, the top floor (F6-00) and bottom floor (F6-01) of the elevators should be set
based on corresponding physical floors.
Assume that there are two elevators in parallel mode. Elevator 1 stops at floor B1, floor 1,
floor 2, and floor 3, while elevator 2 stops at floor 1, floor 3, and floor 4. Now, you need to
set related parameters and HCB addresses according to the following table.
Table 5-10 Parameter setting and HCB addresses of two elevators
Elevator 1
Elevator 2
Number of elevators in
group mode
2
2
Elevator No.
1
2
Actual floor
Physical
floor
HCB
address
HCB display
HCB address
HCB display
B1
1
1
FE-01 = 1101
1
2
2
FE-02 = 1901
2
FE-02 = 1901
2
3
3
FE-03 = 1902
Non-stop floor
but leveling
plate required
FE-03 = 1902
3
4
4
FE-04 = 1903
4
FE-04 = 1903
4
5
5
FE-05 = 1904
Bottom floor
(F6-01)
1
2
Top floor (F6-00)
4
5
Service floor (F6-05)
65535
65531 (not stop at physical floor
3)
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......