Function Code Table NICE3000
new
User Manual
- 124 -
Function
Code
Parameter Name
Setting Range
Default
Unit
Property
FA-24
Communication
interference
0–65535
0
-
●
FA-26
Input state 1
0–65535
0
-
●
FA-27
Input state 2
0–65535
0
-
●
FA-28
Input state 3
0–65535
0
-
●
FA-30
Input state 5
0–65535
0
-
●
FA-31
Output state 1
0–65535
0
-
●
FA-32
Output state 2
0–65535
0
-
●
FA-33
Car input state
0–65535
0
-
●
FA-34
Car output state
0–65535
0
-
●
FA-35
Hall sate
0–65535
0
-
●
FA-36
System state 1
0–65535
0
-
●
FA-37
System state 2
0–65535
0
-
●
FA-46
Hall call
communication state 1
0–65535 (floors 1–16)
0
-
●
FA-47
Hall call
communication state 2
0–65535 (floors 17–32)
0
-
●
FA-48
Hall call
communication state 3
0–65535 (floors 33–40)
0
-
●
Group FB: Door function parameters
Fb-00
Number of door
machine(s)
1–2
1
-
☆
Fb-01
CTB software
00–999
0
-
●
Fb-02
Service floors 1 of door
machine 1
0–65535
65535
-
☆
Fb-03
Service floors 2 of door
machine 1
0–65535
65535
-
☆
Fb-04
Service floors 1 of door
machine 2
0–65535
65535
-
☆
Fb-05
Service floors 2 of door
machine 2
0–65535
65535
-
☆
Fb-06
Door open protection
time
5–99
10
s
☆
Fb-07
Arrival gong output
delay
0–1000
0
ms
☆
Fb-08
Door close protection
time
5–99
15
s
☆
Fb-09
Door re-open times
0–20
0
-
☆
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......