Function
Code
Parameter Name
Setting Range
Default
Unit
Property
FE-32
Elevator function
selection 1
Bit2: Re-leveling function
Bit3: Door pre-open
function
Bit4: Stuck hall call
cancellation
Bit5: Night security floor
function
Bit6: Down collective
selective peak service
Bit7: Parallel peak
service
Bit8: Time-based service
floor function
Bit9: VIP function
Bit11: Car call deletion
Bit12: Hall call deletion
Bit15: Door lock short-
circuit detection
34816
-
☆
FE-33
Elevator function
selection 2
Bit1: Door open holding
at open limit
Bit2: Door close
command not output
upon door close limit
Bit4: Auto reset for RUN
and brake contactor
stuck
Bit5: Slow-down switch
stuck detection
Bit7: Forced door close
Bit8: NO shorting motor
stator contactor
Bit9: Immediate stop
upon re-leveling
Bit13: High-speed
elevator protection
function
Bit15: Opposite door
independent control
36
-
☆
Group Fr: Leveling adjustment parameters
Fr-00
Leveling adjustment
function
0: Disabled
1: Enabled
0
-
★
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......