NICE3000
new
User Manual Description of Function Codes
- 141 -
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F1-15
Rotor resistance
(asynchronous motor)
0.000–30.000
Model
dependent
Ω
★
F1-16
Leakage inductance
(asynchronous motor)
0.00–300.00
Model
dependent
mH
★
F1-17
Mutual inductance
(asynchronous motor)
0.1–3000.0
Model
dependent
mH
★
F1-18
Magnetizing current
(asynchronous motor)
0.01–300.00
Model
dependent
A
★
These parameters are obtained by means of motor auto-tuning. After the motor auto-tuning
is completed successfully, the values of these parameters are updated automatically.
If motor auto-tuning cannot be performed onsite, manually enter the values by referring to
data of the motor with the same nameplate parameters.
Each time F1-01 (Rated motor power) of the asynchronous motor is modified, these
parameters automatically resume to the default values for the standard motor.
Function Code
Parameter Name
Setting Range
Default
Unit Property
F1-19
Shaft Q inductance (torque)
0.00–650.00
3.00
mH
★
F1-20
Shaft D inductance (excitation)
0.00–650.00
3.00
mH
★
F1-21
Back EMF
0–65535
0
-
★
These parameters are obtained by means of motor auto-tuning.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F1-25
Motor type
0: Asynchronous motor
1: Synchronous motor
1
-
★
It is used to set the motor type. This parameter must be set correctly before motor auto-
tuning; otherwise, the motor auto-tuning cannot be performed.
Group F2: Vector Control Parameters
Function Code
Parameter Name
Setting Range Default Unit Property
F2-00
Speed loop proportional gain KP1
0–100
40
-
★
F2-01
Speed loop integral time TI1
0.01–10.00
0.60
s
★
F2-02
Switchover frequency 1
0.00 to F2-05
2.00
Hz
★
F2-00 and F2-01 are PI regulation parameters when the running frequency is smaller than
the value of F2-02 (Switchover frequency 1).
Function Code
Parameter Name
Setting Range Default Unit Property
F2-03
Speed loop proportional gain KP2
0–100
35
-
★
F2-04
Speed loop integral time TI2
0.01–10.00
0.80
s
★
F2-05
Switchover frequency 2
F2-02 to F0-06
5.00
Hz
★
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......