NICE3000
new
User Manual Description of Function Codes
- 167 -
F6-42 Program Control Selection 3
Bit
Function
Description
Default
Bit0
Reserved
-
0
Bit1
Cancelling door
open/close
command at delay
after door open/
close limit
If this function is enabled, the door open/close
command is cancelled at the delay of 1s after door
open/close limit.
0
Bit2
Not judging door
lock state at door
close output
On normal conditions, the system determines that the
door is completely closed only when the door close
limit signal is active and the door lock is applied.
If this function is enabled, the system need not judge
the door lock state.
0
Bit3
Door close
command output
during running
The door close command is output continuously during
the elevator running.
0
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F6-43
Attendant function selection
0–65535
0
-
★
It is used to select the attendant-related elevator functions. "1" indicates that the function is
enabled, and "0" indicates that the function is disabled.
The functions defined by the binary bits are described in the following table.
Table 7-9 Attendant-related functions indicated by bits of F6-43
F6-43 Attendant Function Selection
Bit
Function
Description
Default
Bit0
Calls cancelled after
entering attendant
state
All car calls and hall calls are cancelled after the system
enters the attendant state for the first time.
0
Bit1 Not responding to
hall calls
The car blinks inside, prompting there is hall call, but
the system does not respond.
0
Bit2 Attendant/Automatic
state switchover
If this function is enabled, the setting of F5-00
(Attendant/Normal switchover time) is valid.
0
Bit3 Door close at jogging The elevator door closes after the attendant presses the
door close button manually.
0
Bit4 Automatic door close It is the same as the normal state. After the door open
holding time is reached, the door closes automatically.
0
Bit5
Buzzer tweet at
intervals in attendant
state
When the hall call floor and the car call floor are
different, the buzzer tweets 2.5s at intervals.
0
Bit6
Continuous buzzer
tweet in attendant
state
When the hall call floor and the car call floor are
different, the buzzer tweets continuously.
0
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......