NICE3000
new
User Manual Description of Function Codes
- 169 -
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F6-45
Emergency evacuation
function selection
0–65535
0
-
★
It is used to select the emergency evacuation-related functions. "1" indicates that the
function is enabled, and "0" indicates that the function is disabled.
The functions defined by the binary bits are described in the following table.
Table 7-11 Emergency evacuation functions indicated by bits of F6-45
F6-45 Emergency Evacuation Function Selection
Bit
Function
Description
Default
Bit0
Direction
determine mode
0 Automatically
calculating
direction
1
Load direction
determining (based
on load cell data or
half-load signal)
1
Direction
of nearest
landing
floor
0
Bit1
0
0
0
0
Bit2
Stopping at
evacuation
parking floor
During evacuation running, the elevator arrives at the
evacuation parking floor set in F6-49 (it must be a non-zero
value and is a service floor). Otherwise, the elevator stops
at the nearest floor.
0
Bit3
Door open at
single leveling
signal
During evacuation running, when the elevator arrives at
the target floor and a leveling signal is active, the elevator
decelerates to stop.
0
Bit4
Compensation at
startup
The non-load-cell startup is still valid in the process of
evacuation running.
0
Bit5 to
Bit7
Reserved
-
0
Bit8
Emergency
running time
protection
If the elevator does not arrive at the required floor after
50s emergency evacuation running time, Err33 is reported.
In this case, the function of switching over shorting stator
braking mode to controller drive based on the time setting
cannot be implemented.
0
Bit9
Reserved
-
0
Bit10 Emergency
buzzer output
The buzzer tweets at intervals in the emergency evacuation
running state.
0
Bit11 Reserved
-
0
Bit12
Shorting stator
braking mode
switched over to
controller drive
It enables the function of switching over shorting stator
braking mode to controller drive.
0
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......