Description of Function Codes NICE3000
new
User Manual
- 176 -
Group F9: Time Parameters
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F9-00
Idle time before
returning to base floor
0–240
10
min
☆
It is used to set the idle time of the elevator before returning to the base floor.
When the idle time of the elevator exceeds the setting of this parameter, the elevator returns
to the base floor.
If this parameter is set to 0, it becomes invalid.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F9-01
Time for fan and lamp
to be turned off
0–240
2
min
☆
It is used to set the time that fan and lamp stays ON before being turned off automatically.
If there is no running command in the automatic running state, the system turns off the fan
and lamp automatically after the time set in this parameter.
If this parameter is set to 0, it becomes invalid.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F9-02
Motor running time limit
0–45
45
s
★
It is used to set the running time limit of the motor.
In normal running state, if the continuous motor running time in the same direction between
two adjacent floors exceeds the setting of this parameter but no leveling signal is received,
the system will perform protection.
This parameter is mainly used for over-time protection in the case of steel rope slipping on
the traction sheave.
If this parameter is set to a value smaller than 3s, it becomes invalid.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F9-03
Clock: year
2000–2100
Current year
YYYY
☆
F9-04
Clock: month
1–12
Current month
MM
☆
F9-05
Clock: day
1–31
Current day
DD
☆
F9-06
Clock: hour
0–23
Current hour
HH
☆
F9-07
Clock: minute
0–59
Current minute
MM
☆
These parameters are used to set the current date and time of the system.
Timekeeping is supported at power failure. You need to set the current system time correctly
so that functions related to the time can be implemented.
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......