Description of Function Codes NICE3000
new
User Manual
- 178 -
Function Code
Parameter Name
Setting Range
Default
Unit
Property
FA-02
Display in stop state
1–65535
65535
-
☆
It is used to set the parameters displayed on the keypad when the elevator is in the stop
state.
A total of 16 parameters can be displayed at stop. The use is the same as that of FA-01.
The 16 binary bits correspond to the stop parameters listed in the following table.
Table 7-14 Stop parameters corresponding to 16 bits of FA-02
Bit
Parameter Name
Default
Bit
Parameter Name
Default
Bit0
Running speed
1
Bit8
Slow-down distance at
rated speed
1
Bit1
Bus voltage
1
Bit9
CTB input state
1
Bit2
Input terminal low bits
1
Bit10
CTB output state
1
Bit3
Input terminal high bits
1
Bit11
System state
1
Bit4
Output terminal
1
Bit12
Reserved
0
Bit5
Current floor
1
Bit13
Reserved
0
Bit6
Current position
1
Bit14
Reserved
0
Bit7
Car load
1
Bit15
Reserved
0
The running and stop parameters of the NICE3000
new
system are the important references
for engineers to perform commissioning on site. The parameters are described as follows:
1) Running speed: indicates the actual running speed of the elevator.
Its maximum value is F0-03 (Maximum running speed), in unit of m/s.
2) Set speed: indicates the set speed of the NICE3000
new
system during elevator running.
It is the running speed calculated by the system theoretically at which the elevator
should run. Its unit is m/s.
3) Bus voltage: indicates the DC bus voltage of the NICE3000
new
system, in unit of m/s.
4) Output voltage: indicates the effective value of the equivalent voltage of the PWM wave
output by the NICE3000
new
system, in unit of V.
5) Output current: indicates the effective value of the actual current when the NICE3000
new
system drives the motor to turn, in unit of A.
6) Output frequency: indicates the actual frequency of the motor during running. It has a
fixed corresponding relationship with the running speed. The unit is Hz.
7)
Input terminal low bits: indicate the meaning of input terminals by bit. "1" indicates that
the signal is active.
A total of 16 bits are defined as below:
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......