Description of Function Codes NICE3000
new
User Manual
- 198 -
Function Code
Parameter Name
Setting Range
Default
Unit
Property
FE-32
Elevator function selection 1
0–65535
34816
-
☆
It is used to set the elevator functions. "1" indicates that the function is enabled, and "0"
indicates that the function is disabled.
FE-32 Elevator function selection 1
Bit
Function
Description
Default
Bit0 Reserved
-
0
Bit1 Reserved
-
0
Bit2 Re-leveling
function
The elevator performs re-leveling at a low speed with
door open. An external shorting door lock circuit contactor
needs to be used together.
0
Bit3 Door pre-open
function
During normal stop, when the elevator speed is smaller
than a certain value and the door zone signal is active,
the system shorts the door lock by means of the shorting
door lock circuit contactor and outputs the door open
signal, implementing door pre-open. This improves the
elevator use efficiency.
0
Bit4 Stuck hall call
cancellation
The system automatically identifies the state of the hall
call buttons. If the state is abnormal, the system cancels
the stuck hall call.
0
Bit5
Night security floor
function
From 10:00 p.m to 6:00 a.m., the elevator runs to the
security floor first every time, stops and opens the door,
and then runs to the destination floor.
0
Bit6
Down collective
selective peak
service
The peak service at down collective selective is used.
0
Bit7 Parallel peak
service
The peak service in parallel control is used.
0
Bit8
Time-based
service floor
function
For details, see the description of related parameters in
group F6.
0
Bit9 VIP function
The VIP function is used.
0
Bit10 Reserved
-
0
Bit11 Car call deletion
A call can be deleted by pressing the button twice
consecutively.
1
Bit12 Hall call deletion
0
Bit13 Reserved
-
0
Bit14 Reserved
-
0
Bit15 Door lock short-
circuit detection
After detecting the door lock short-circuit, the system
reports fault Err53.
1
Function Code
Parameter Name
Setting Range
Default
Unit
Property
FE-33
Elevator function selection 2
0–65535
36
-
☆
It is used to set the elevator functions. "1" indicates that the function is enabled, and "0"
indicates that the function is disabled.
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......