NICE3000
new
User Manual Mechanical and Electrical Installation
- 35 -
Figure 3-2 Diagram of mounting holes
4-M5x15 bolt
4-M5×15 screw
4-M5x15 washer
Fixing
backplane
NICE3000
new
integrated
elevator
controller
4-M6×15 bolt
4-M6×15 screw
4-M6×15 washer
1.1 kW
≤
P
≤
15 kW
18.5 kW
≤
P
≤
45 kW
2.5 Nm
With fixing
washer
Fastening
torque
3.5 Nm
With fixing
washer
Fastener
The controller is generally installed in the control cabinet of the elevator equipment room.
Pay attention to the following points when designing the control cabinet:
1. The temperature inside the cabinet must not rise to 10°C higher than the temperature
outside the cabinet.
2. A closed control cabinet must be configured with a fan (or other air cooling device such as
air conditioner) to ensure air circulation.
3. The air from the fan must not blow directly to the drive unit because this easily causes
dust adhesion and further a fault on the drive unit.
4. A vent must be available at bottom of the control cabinet to form bottom-up air flow, which
prevents heat island effect on the surface of components or partial thermal conductivity
effect.
5. If the fan cannot meet the cooling requirements, install an air conditioner in the cabinet
or in the equipment room. Note that the temperature inside the cabinet must not be too low;
otherwise, condensation may occur, causing short-circuit of components.
6. For special environment where the temperature is high but cannot be reduced effectively,
de-rate the controller during use.
3.1.3 Terminal Arrangement and Wiring Description
■
Terminal Arrangement
The following figure shows terminal arrangement of the NICE3000
new
.
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......