Set-up
Technical Handbook
019722-101 Rev. 05
31
SC-350/360
7.10 8 - Adjustment of Sensitivity
of Hopper (SC 360)
This function sets the time delay between the stop of the flow of
coins and the restart of the hopper.
Press
Q
until the number “8” is shown at the far left of the display.
The display also shows four other numbers which are detailed below:
Example (default setting):
(a), (b) and (c) Time delay settings
The time delay is set by (a), (b) and (c) and varies between 0 and
1990 ms.
d) Not used (=0)
7.11 Accessing Statistics Registers
To get information about the use of the machine, use the following
functions:
a) Press and hold
Q
and
ACC
at the same time, while switching the
machine
On
.
b) When the display changes from showing a row of “8”s to
“S t A t”, release
Q
and
ACC
.
The machine is now in the
statistics
mode.
Total number of times the motor has started and reversed:
Hold down
M
. The display shows “S t A r t” and then the
number of times that the motor has started and reversed since
the last time the value was reset.
>>>
Time delay (ms)
a
b
c
0
0 (default)
0 (default)
0 (default)
10-90
0
0
1-9
100-990
0
1-9
0-9
1000
1
0
0
1010-1090
1
0
1-9
1100-1990
1
1-9
0-9
8
0
0
0
0
a (0-1) b (0-9) c (0-9) d (0-1)