Precautions: 00-2
• Never reuse a circlip. When installing a
new circlip, take care not to expand the
end gap larger than required to slip the
circlip over the shaft. After installing a
circlip, always ensure that it is completely
seated in its groove and securely fitted.
• Use a torque wrench to tighten fasteners
to the specified torque. Wipe off grease
and oil if a thread is smeared with them.
• After reassembling, check parts for
tightness and proper operation.
• To protect the environment, do not
unlawfully dispose of used motor oil,
engine coolant and other fluids: batteries,
and tires.
• To protect Earth’s natural resources,
properly dispose of used vehicle and parts.
Precautions for Electrical Circuit Service
B931H20000003
When handling the electrical parts or servicing the FI
systems, observe the following points for the safety of
the systems.
Electrical Parts
Connector / Coupler
• Faulty FI system is often related to poor electrical
contact of connector/coupler. Before servicing
individual electronic part, check electrical contact of
the connector/coupler.
• When connecting a connector, be sure to push it in
until a click is felt.
• With a lock type coupler, be sure to release the lock
when disconnecting, and push it in fully to engage the
lock when connecting.
• When disconnecting the coupler, be sure to hold the
coupler body and do not pull the lead wires.
• Inspect each terminal on the connector/coupler for
looseness or bending.
• Push in the coupler straightly. An angled or skewed
insertion may cause the terminal to be deformed,
possibly resulting in poor electrical contact.
• Inspect each terminal for corrosion and
contamination. The terminals must be clean and free
of any foreign material which could impede proper
terminal contact.
• Before refitting the sealed coupler, make sure its seal
rubber is positioned properly. The seal rubber may
possibly come off the position during disconnecting
work and if the coupler is refitted with the seal rubber
improperly positioned, it may result in poor water
sealing.
• Inspect each lead wire circuit for poor connection by
shaking it by hand lightly. If any abnormal condition is
found, repair or replace.
• When taking measurements at electrical connectors
using a tester probe, be sure to insert the probe from
the wire harness side (backside) of the connector/
coupler.
I310G1000001-01
1. Coupler
2. Probe
I310G1000002-01
I310G1000003-02
2
1
I649G1000013-02
Summary of Contents for 2009 LT-A500XP
Page 2: ......
Page 4: ......
Page 14: ...00 9 Precautions ...
Page 224: ...1E 3 Engine Lubrication System EXHAUST SIDE INTAKE SIDE I931H1150003 02 ...
Page 304: ...1K 4 Exhaust System ...
Page 346: ...2D 5 Wheels and Tires ...
Page 438: ...3D 26 Propeller Shafts ...
Page 482: ...4D 6 Parking Brake ...
Page 512: ...5A 28 Automatic Transmission ...
Page 624: ...Prepared by December 2008 Part No 99500 44080 03E Printed in U S A 624 ...