ELECTRICAL 4-7
TROUBLESHOOTING
NOTE:
Before troubleshooting the electric starter system, make sure the followings:
•
Battery is fully charged.
•
All cables / wires are securely connected.
•
Shift is in “NEUTRAL” position.
Circuit check schematic
Check starter motor.
(See page 4-14.)
Sub cable
1
+
-
3
Starter motor
GND
Ignition switch
Neutral switch
ST
BAT
GND
GND
Neutral
switch
30A Fuse
GND
GND
Battery
Starter motor relay
2
Starter motor will not run.
Check if there is “click” sound of relay when
turning ignition switch “START”.
Is there “click” sound?
Measure voltage at terminal
2
while turning
ignition switch at “START”.
It must be above 12 V. Is result OK?
Measure voltage at terminal
3
while turning
ignition switch “START”.
It must be above 12 V. Is result OK?
Starter motor failure
Sub cable failure
Measure voltage at
terminal
1
. It must
be above 12V.
Is result OK?
Check if 30A fuse is
in good condition.
Is result OK?
Check ignition switch
function.
(See page 4-8.)
Is result OK?
Check function of both
neutral switches. (See
page 4-8 and 4-9.)
Is result OK?
Check starter motor
relay.
(See page 4-9.)
Starter motor relay
failure
Battery cable
failure
30A fuse
failure
Ignition switch
failure
Neutral switch
failure
YES
YES
YES
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO