8-14 POWER TRIM AND TILT
PTT MOTOR INSTALLATION
Installation is reverse order of removal with the special atten-
tion to the following steps.
1. Ensure that the drive joint
1
is aligned and firmly inserted
into the gear pump assembly.
2. Fit the O-ring
2
to the PTT motor.
3. Check the level of the PTT fluid contained in the PTT pump
case. If the level is low, add the recommended PTT fluid
until the level with the mating surface of the PTT motor.
4. Ensure that the faces of the PTT motor and the pump unit
are free of dirt or debris.
When attaching the PTT motor to the PTT pump case, en-
sure that the tip of the armature shaft fits firmly into the
drive joint
1
.
5. Tighten the four bolts to the specified torque.
"
PTT motor screw: 5 N.m (0.5 kg-m, 3.6 lb-ft)
6. Pour the recommended PTT fluid into the reservoir until
the specified level.
7. Perform the air bleeding procedure.
See the AIR BLEEDING section on the page 8-3.
Ar
Armature shaft
mature shaft
Armature shaft