9-20 LOWER UNIT
#
Do not exceed pressure of 110 kPa (1.1 kg/cm
2
, 15.6
psi) or damage to oil seals will result.
4. Once stabilized, the pressure should remain steady for at
least 5 min.
If the pressure does not fall, sealing performance is correct.
WATER PUMP
1. Place the dowel pins
1
, the under panel gasket
2
and the
under panel
3
into position.
2. Insert the key
4
in the driveshaft and slide the impeller
5
onto the driveshaft, ensuring that the key and the keyway
are aligned.
PROPELLER INSTALLATION
1. Install the spacer
1
and the propeller stopper
2
onto the
propeller shaft, then slide on the propeller
3
.
2. Fit the spacer
4
, the washer
5
and the nut
6
, then tighten
the nut to the specified torque.
&
Propeller nut: 55 N.m (5.5 kg-m, 40.0 lb-ft)
3. Push the cotter pin
7
through the nut and the shaft, then
bend to secure.
3. Install the pump case
1
while rotating the driveshaft clock-
wise to flex the impeller vanes in correct direction.
4. Tighten the four pump case bolts
2
to the specified torque.
&
Pump case bolt: 20 N.m (2.0 kg-m, 14.5 lb-ft)