ELECTRICAL SYSTEM 6-15
STARTER RELAY INSPECTION
• Remove the seat. (
5-2)
• Remove the starter relay
1
.
• First check the insulation between
C
and
D
terminals with
the multi-circuit tester.
• Then apply 12 V to
A
and
B
terminals and check for continu-
ity between the
C
and
D
terminals. If the starter relay clicks
and continuity are found, the relay is OK.
\
09900-25008: Multi-circuit tester set
=
Tester knob indication: Continuity test (
?
)
Measure the relay coil resistance between the
A
and
B
termi-
nals using the multi-circuit tester. If the resistance is not within
the specified value, replace the starter relay with a new one.
\
09900-25008: Multi-circuit tester set
V
Tester knob indication: Resistance (
Ω
)
Starter relay resistance: 70 – 90
Ω
Do not apply battery voltage to the starter relay for
more than five seconds, since the relay coil may over-
heat and get damaged.