7-9 SERVICING INFORMATION
BATTERY
Complaint
Symptom and possible causes
Remedy
“Sulfation”, acidic
white powdery sub-
stance or spots on
surface of cell
plates.
1. Cracked battery case.
2. Battery has been left in a run-down condition for
a long time.
Replace the battery.
Replace the battery.
Battery runs down
quickly.
1. Trouble in charging system.
2. Cell plates have lost much of their active
material as a result of overcharging.
3. Internal short-circuit in battery.
4. Too low battery voltage.
5. Too old battery.
Check the generator, regu-
lator/rectifier and circuit
connections and make nec-
essary adjustments to
obtain specified charging
operation.
Replace the battery, and
correct the charging sys-
tem.
Replace the battery.
Recharge the battery fully.
Replace the battery.
Battery “sulfation”.
1. Incorrect charging rate.
(When not in use battery should be checked at
least once a month to avoid sulfation.)
2. The battery was left unused in a cold climate for
long.
Replace the battery.
Replace the battery if badly
sulfated.