SVAN 948 USER MANUAL
4 - 19
The change of the channel is achieved by pressing the
<SHIFT>
with
<
>
or
<SHIFT>
with
<
>
push-buttons.
The view of the displays in one profile presentation – the changing of the channels
3 PROFILES mode of the measurement results presentation
In
3 PROFILES
mode of result’s presentation the selected results from each channel are displayed
in three consecutive lines. In each line the name of the measurement result, its value and the units are
presented. The channels are separated by two straight horizontal lines. These lines are doted in other
modes than vibration level meter.
The view of the displays in 3 PROFILES presentation – the changing of the channels
On the display there are show three lines. User is able to rewind view by pressing the
<SHIFT>
with
<
>
or
<SHIFT>
with
<
>
push-buttons. The change of the active channel (this in which the name is
displayed inversely) is performed by means of the
<SHIFT>
with
<
>
or
<SHIFT>
with
<
>
push-
buttons. The switching between the simultaneously calculated results is performed by means of the
<
>
,
<
>
push-buttons.
Presentation of time history - PLOT
The
PLOT
mode of results presentation is available if data from at least one channel are logged in
the buffer’s file. If the
BUFFERS
position in
BUFFERS SETUP
sub-list is switched
ON
but in the selected
channel there was nothing switched on (
[
√
√√
√
]
), the
NO RESULTS
text is displayed after the first input to this
mode (see Figure below). When the
BUFFERS
is selected as non-active
BUFFER:OFF
and it is set for all
channels, the
PLOT
mode of results presentation is skipped.
There are
PLOT
display, when the
BUFFERS
position is switched
ON
and user selected position to
display in
BUFFERS SETUP/ CHANNEL x
(
[
√
√√
√
]
)
The view of the display in the PLOT mode when there is nothing in the buffer to be displayed (after setting
PLOT as active)
In the
PLOT
presentation the results logged in the file of the buffer of the instrument are also given
on the display in the time history form. Each line corresponds to one measurement result (the results are
registered with the step set in the
BUF. STEP
position of the
MEASURE SETUP
sub-list
(path: MENU /
Summary of Contents for SVAN 948
Page 1: ...SVAN 948 SOUND AND VIBRATION DATA LOGGER USER S MANUAL SVANTEK Sp z o o WARSAW June 2004...
Page 19: ...SVAN 948 USER MANUAL 2 6 The view of the rear panel of the SVAN 948 instrument in 1 1 scale...
Page 25: ...SVAN 948 USER MANUAL 3 6 Control diagram of the INPUT list...
Page 28: ...SVAN 948 USER MANUAL 3 9 Control diagram of the DISPLAY list...
Page 30: ...SVAN 948 USER MANUAL 3 11 Control diagram of the FILE list...
Page 32: ...SVAN 948 USER MANUAL 3 13 Control diagram of the AUX FUNCTION list...
Page 36: ...SVAN 948 USER MANUAL 3 17...
Page 37: ...SVAN 948 USER MANUAL 3 18 Control diagram of the SETUP list...